Support
Support &
Trouble Shooting

CleanStation Trouble Shooting

Need to contact Tech Suport? Click Here

CS2

Machine not starting:
– Check that the water level is high enough to float the level switch float. When the top two holes in the jet plate are covered or the water level is about 1″ from the top of the tank.

Machine will not drain:
– Check that the 3-way valve is fully rotated to “Drain Tank” position, to active the magnetic switch.

Machine Not heating:
– Check that the controller set point is set correctly.

More questions? Contact Tech Support: Click Here


DT3

Machine not starting:
– Check that the water level is high enough to float the level switch float. When the top two holes in the jet plate are covered or the water level is about 1″ from the top of the tank.

Not heating:
– Check that the controller set point is set correctly.

More questions? Contact Tech Support: Click Here


DT3-M

Machine not starting:
– Check that the water level is high enough to float the level switch float. When the top two holes in the jet plate are covered or the water level is about 1″ from the top of the tank.

More questions? Contact Tech Support: Click Here


CS2P

Machine not starting:
– Check that the water level is high enough to float the level switch float. When the top two holes in the jet plate are covered or the water level is about 1″ from the top of the tank.

Machine will not drain:
– Check that the 3-way valve is fully rotated to “Drain Tank” position, to active the magnetic switch.

Not heating:
– Check that the controller set point is set correctly.

More questions? Contact Tech Support: Click Here


XL-Plus

Machine not starting:
– Check that the water level is high enough to float the level switch float.
– Check that the 3-way valve is fully rotated to “Clean Parts” position.

Machine will not drain:
– Check that the 3-way valve is fully rotated to “Drain Tank” position, to active the magnetic switch.

Machine Not heating:
– Check that the controller set point is set correctly.


Contact Tech Support

(Red Asterisk = Required Field)

Technical Support
First
Last
reCAPTCHA